3D physical chemistry lab
Four more practicals on a 3D lab bench, driven by real calculations. Measure how fast marble reacts with acid, find the energy released by a reaction, electrolyse solutions and weigh the electrodes, and separate dyes by chromatography.
Keyboard: ← → next part · F full screen · G guided tour · L labels · Q quiz · O overview
How real is it? Rates come from a collision-theory model (rate ∝ [H⁺] × surface area × an Arrhenius temperature factor, activation energy 45 kJ/mol), the calorimetry includes the heat capacity of the solution and heat lost to the room, electrolysis products follow Faraday’s laws from the current and time, and chromatography uses measured-style Rf values with a solvent front that slows as it rises. Small random errors are built in, like a real lab.
The four experiments
1. Rates of reaction
CaCO₃(s) + 2HCl(aq) → CaCl₂(aq) + H₂O(l) + CO₂(g). Change the acid concentration, the temperature or the size of the marble pieces and compare the volume–time curves. Each run is kept on the graph in a new colour. Switch to hydrogen peroxide (2H₂O₂ → 2H₂O + O₂) to compare catalysts: manganese(IV) oxide, copper(II) oxide or none, as powder or lumps.
2. Energy changes
| Reaction | Data-book ΔH |
|---|---|
| Neutralisation: HCl(aq) + NaOH(aq) → NaCl(aq) + H₂O(l) | -57.1 kJ/mol |
| Displacement: Zn(s) + CuSO₄(aq) → ZnSO₄(aq) + Cu(s) | -217 kJ/mol |
| Dissolving (endothermic): NH₄NO₃(s) → NH₄⁺(aq) + NO₃⁻(aq) | +25.7 kJ/mol |
Record the temperature every 30 seconds before and after mixing, then use q = mcΔT and ΔH = −q ÷ n. Extrapolating the cooling line back to the time of mixing corrects for heat loss.
3. Electrolysis
| Electrolyte | Cathode (−) | Anode (+) |
|---|---|---|
| Copper sulfate, carbon electrodes | Copper is deposited: Cu²⁺ + 2e⁻ → Cu | Oxygen bubbles: 4OH⁻ → O₂ + 2H₂O + 4e⁻ (or 2H₂O → O₂ + 4H⁺ + 4e⁻) |
| Copper sulfate, copper electrodes | Copper is deposited: Cu²⁺ + 2e⁻ → Cu | The copper anode dissolves: Cu → Cu²⁺ + 2e⁻ |
| Sodium chloride solution (brine) | Hydrogen bubbles: 2H₂O + 2e⁻ → H₂ + 2OH⁻ | Chlorine bubbles: 2Cl⁻ → Cl₂ + 2e⁻ |
| Dilute sulfuric acid | Hydrogen bubbles: 2H⁺ + 2e⁻ → H₂ | Oxygen bubbles: 2H₂O → O₂ + 4H⁺ + 4e⁻ |
4. Chromatography
Rf = distance moved by the spot ÷ distance moved by the solvent. A mixture gives several spots; a pure substance gives one. Try ethanol instead of water: the Rf values change, and the purple dye that stays on the baseline in water moves in ethanol.
Questions students ask
How do you measure the rate of a reaction that makes a gas?
Collect the gas in a gas syringe (or an upturned measuring cylinder) and record the volume every 10 or 30 seconds. Plot volume against time: the gradient is the rate. The steepest part, at the start, is the initial rate.
Why is my measured enthalpy change smaller than the data-book value?
Heat is lost to the surroundings and absorbed by the cup and thermometer, so the temperature change is too small. Use a lid, insulate the cup, and extrapolate the cooling line back to the time of mixing to correct for heat loss.
How do you calculate the mass deposited in electrolysis?
Charge Q = current × time (in seconds). Moles of electrons = Q ÷ 96,485. Use the half-equation: Cu²⁺ + 2e⁻ → Cu, so moles of copper = moles of electrons ÷ 2. Mass = moles × 63.5.
What is an Rf value?
Rf = distance travelled by the spot ÷ distance travelled by the solvent, both measured from the baseline. It is always between 0 and 1, and the same substance gives the same Rf in the same solvent.
More chemistry
Connected tools
The same idea from another angle, across the site.